Short answer: divide the battery’s watt-hours by the device’s real running watts, then knock off about 15 percent for inverter losses. A 1,000 Wh power station runs a 40-watt CPAP for roughly 21 hours, a full-size refrigerator for 12 hours, a Wi-Fi router for two and a half days, and a 1,500-watt space heater for about half an hour. The chart below does that math for five battery sizes and sixteen of the devices people actually plug in during an outage, so you can find your own gear and read across.
The Runtime Chart
Runtime here is calculated as usable energy (rated watt-hours times 0.85) divided by the device’s typical draw. The 0.85 factor covers DC-to-AC inverter losses and the small reserve most battery management systems hold back. Device draws are typical figures for current models measured at the wall; your unit may differ, and the section after the chart explains how to check yours in five minutes.
| Device (typical draw) | 300 Wh | 500 Wh | 1,000 Wh | 2,000 Wh | 3,600 Wh |
|---|---|---|---|---|---|
| LED lamp (10 W) | 26 h | 42 h | 85 h | 170 h | 310 h |
| Wi-Fi router and modem (15 W) | 17 h | 28 h | 57 h | 110 h | 200 h |
| CPAP without humidifier (40 W) | 6.4 h | 11 h | 21 h | 42 h | 76 h |
| CPAP with heated humidifier (90 W) | 2.8 h | 4.7 h | 9.4 h | 19 h | 34 h |
| Laptop, working (50 W) | 5.1 h | 8.5 h | 17 h | 34 h | 61 h |
| 32-inch LED TV (40 W) | 6.4 h | 11 h | 21 h | 42 h | 76 h |
| 55-inch LED TV (100 W) | 2.5 h | 4.2 h | 8.5 h | 17 h | 31 h |
| Box fan (50 W) | 5.1 h | 8.5 h | 17 h | 34 h | 61 h |
| Mini fridge, averaged over cycling (35 W) | 7.3 h | 12 h | 24 h | 49 h | 87 h |
| Full-size refrigerator, averaged over cycling (70 W) | 3.6 h | 6.1 h | 12 h | 24 h | 44 h |
| Chest freezer, averaged over cycling (40 W) | 6.4 h | 11 h | 21 h | 42 h | 76 h |
| Electric blanket (100 W) | 2.5 h | 4.2 h | 8.5 h | 17 h | 31 h |
| Starlink standard kit (75 W) | 3.4 h | 5.7 h | 11 h | 23 h | 41 h |
| Microwave, 1,000 W (minutes of cooking) | 15 min | 26 min | 51 min | 102 min | 184 min |
| Space heater on low (750 W) | 20 min | 34 min | 1.1 h | 2.3 h | 4.1 h |
| Space heater on high (1,500 W) | 10 min | 17 min | 34 min | 1.1 h | 2.0 h |
Phone charging is easier to think of in charges rather than hours. A modern phone battery holds about 15 Wh, so a 300 Wh station gives roughly 17 full charges, a 1,000 Wh station about 56, and a 2,000 Wh station more than 100. A laptop with a 60 Wh battery gets 4 full charges from a 300 Wh unit and 14 from a 1,000 Wh unit.
How to Read the Chart for Your Own Gear
The only number you need from your device is its running watts, and the sticker on the back is usually the wrong place to find it. Nameplate ratings show the maximum the power supply can deliver, not what the device pulls in normal use. A laptop with a 65-watt charger typically draws 20 to 50 watts while you work. A 55-inch TV rated at 180 watts averages closer to 100 in a normal picture mode.
The reliable way to know is a plug-in power meter. A basic plug-in watt meter costs less than a tank of gas, and ten minutes of measuring your fridge, your CPAP and your router will tell you more than any chart. Once you have the number, the formula is:
Runtime in hours = (battery Wh x 0.85) / device watts
Worked example: a 1,024 Wh station and a fridge that averages 85 watts across its compressor cycles. 1,024 x 0.85 = 870 usable Wh. 870 / 85 = about 10 hours. If you also leave a 15-watt router on, add the two draws first: 870 / 100 = 8.7 hours.
Why Refrigerators and Freezers Are Special
Three rows in the chart say “averaged over cycling,” and that phrase matters. A refrigerator compressor draws 100 to 200 watts while it runs, but it only runs about a third of the time, so the average across an hour is far lower than the running figure. That is why a 1,000 Wh station that “should” die in five hours on a 150-watt fridge actually lasts 10 to 14 hours in practice.
Two things shorten that. The startup surge when the compressor kicks on can reach 800 to 1,200 watts for a fraction of a second, which is why small 300 Wh units with a 300-watt inverter often cannot start a full-size fridge at all. And every time the door opens, the compressor runs longer to recover. During an outage, keep the door shut and the fridge will coast for hours between cycles. We cover the door-open math and which sizes can actually start a compressor in how long a power station runs a refrigerator.
Why the Sticker Wh Is Not What You Get
A 1,000 Wh label does not mean 1,000 Wh at the outlet. Four things eat into it:
- Inverter losses. Converting battery DC to 120-volt AC costs 8 to 15 percent, more at very light loads where the inverter’s own idle draw (5 to 15 watts) becomes a large share of the total.
- Battery reserve. Most units shut down at 2 to 5 percent to protect the cells rather than running to a true zero.
- Cold. Lithium cells deliver noticeably less below about 40 F, and most units will not charge below freezing at all. Keep the station indoors in winter.
- Age. LiFePO4 cells hold about 80 percent of original capacity after 3,000 or more full cycles; older NMC chemistry gets there after 500 to 800. The chemistry question is a big part of choosing between brands, which we compare in EcoFlow vs Bluetti vs Jackery.
The 0.85 factor in the chart is a middle-of-the-road allowance for the first two. In cold weather or with a well-used battery, plan on 0.75.
Running Several Things at Once: Three Realistic Overnight Budgets
Nobody runs a single device. Here is what a full night looks like at three battery sizes, using the same draws as the chart.
300 Wh unit, one night of essentials. Phone charging (30 Wh) plus a router (15 W x 10 hours = 150 Wh) plus a lamp for three hours (30 Wh) totals 210 Wh, well within the 255 Wh usable. Add a CPAP and the router has to go. A 300 Wh unit is a one-job battery.
1,000 Wh unit, one night with medical gear. A CPAP without humidifier for 8 hours (320 Wh), the router all night (150 Wh), phones (60 Wh) and a lamp (30 Wh) totals 560 Wh, leaving about 290 Wh for a fridge to coast through the night on a few compressor cycles. This is the most common sweet spot for a household, and it is why the 1,000 Wh class dominates our best portable power stations for home backup list.
2,000 Wh unit, 24 hours of a working household. Full-size fridge for 24 hours (1,680 Wh averaged) plus router (360 Wh) plus a laptop for 8 hours (400 Wh) plus phones and lights (150 Wh) totals about 2,590 Wh, which is more than the 1,700 usable. You either recharge from solar during the day, which is what the 2,000 Wh class is designed for, or you run the fridge 12 hours on and 12 off and the budget closes with room to spare.
The lesson from the third budget is that above 1,000 Wh, the recharge plan matters as much as the capacity. See how to position solar panels for a power station for what a 200 to 400 watt panel realistically returns in a day.
What Each Battery Size Is Actually For
| Class | Typical inverter | Best fit | Cannot do |
|---|---|---|---|
| 300 Wh | 300 to 600 W | Phones, lamps, router, a fan, a CPAP for one night | Start a full-size fridge, run any heating appliance |
| 500 Wh | 500 to 800 W | All of the above plus a mini fridge or a laptop workday | Microwave, toaster, coffee maker at full power |
| 1,000 Wh | 1,200 to 2,000 W | Fridge overnight, CPAP plus router plus lights, short microwave use | Space heater for more than an hour, well pump |
| 2,000 Wh | 2,000 to 3,000 W | Fridge plus freezer for a day, small window AC for a few hours, power tools | Central AC, electric water heater, dryer |
| 3,600 Wh and up | 3,000 to 7,200 W | Two days of essentials, 240-volt well pump, a subpanel of circuits | Whole-home loads without a solar or generator recharge plan |
If your must-run list includes a well pump, a sump pump or a furnace blower, the inverter’s continuous and surge wattage matters more than the watt-hours, and that is the point where a generator starts making more sense than a bigger battery. Our power station vs generator comparison lays out where the line falls.
Six Ways to Stretch Every Watt-Hour
- Use DC outputs when you can. Charging a phone or laptop from the USB-C port skips the inverter and saves 10 to 15 percent.
- Turn the AC inverter off when nothing needs it. On most units the inverter idles at 5 to 15 watts even with nothing plugged in. Over a night that is 100 Wh wasted.
- Run the CPAP without the heated humidifier. It more than doubles the draw, as the chart shows. Use a heat-moisture exchanger for outage nights instead.
- Cycle the fridge. A closed fridge holds safe temperature for about four hours; a full freezer for 24 to 48 hours. Twelve hours on, twelve off, with the door shut, halves fridge consumption. Details in keeping food safe during a power outage.
- Heat the person, not the room. An electric blanket at 100 watts does more for sleep than a space heater at 1,500 watts, and lasts 15 times longer on the same battery. More cold-weather tactics in staying warm in a winter power outage.
- Recharge at every opportunity. Car 12-volt port during a supply run, a neighbor’s generator, a 200-watt panel on the porch. Each hour of daylight on a decent panel is 100 to 150 Wh back in the bank.
Frequently Asked Questions
How long will a 1,000 Wh power station run a refrigerator?
About 10 to 14 hours for a full-size refrigerator with the door kept closed, because the compressor only runs about a third of the time. A mini fridge runs roughly 24 hours on the same unit.
How long will a 500 Wh power station run a CPAP?
Around 11 hours without the humidifier, which covers a full night with margin. With the heated humidifier on, expect under 5 hours. If CPAP is your main reason for buying, see how long a power station runs a CPAP for a machine-by-machine breakdown.
Can a power station run a space heater?
Technically yes if the inverter is rated above 1,500 watts, but even a 2,000 Wh unit gives barely an hour on high. Resistance heating is the worst possible use of a battery. Use an electric blanket, a propane indoor-rated heater, or a generator for heat.
Why does my power station die faster than the chart says?
Usually one of four reasons: the device draws more than you assumed (measure it), the inverter is left on with nothing running, the unit is cold, or the battery has aged. The 0.85 factor in the chart assumes a healthy battery at room temperature.
Is a bigger battery always better?
Not for portability or price. A 300 to 500 Wh unit weighs 7 to 15 pounds and fits in a closet; a 3,600 Wh unit weighs 60 to 100 pounds and belongs on a cart. Buy for the longest realistic outage you plan for, and remember that above 1,000 Wh a solar panel to recharge often beats a second battery. Budget options are covered in the best power stations under $500.