Short answer: Depth of discharge (DoD) is the share of a battery’s stored energy you are allowed to use before the system shuts off. A battery rated 10 kWh nominal with 90% DoD gives you 9 kWh usable, and after about 90% inverter efficiency, roughly 8.1 kWh at your outlets. If that battery also cycles daily down to a 30% backup reserve, an outage that starts at the wrong moment may leave you with only about 2.4 kWh of AC power.
What depth of discharge actually means
Depth of discharge is the percentage of a battery’s capacity that has been drained. If a 10 kWh battery is run down until 2 kWh remain, it has gone through an 80% depth of discharge. When a spec sheet lists a maximum DoD, it is telling you how far the battery management system will let you go before it stops delivering power to protect the cells.
That limit matters because the capacity in the headline, often called nominal or total capacity, is not the number that runs your refrigerator. The usable number is. And during an outage, the energy you actually get is smaller still, after conversion losses and after accounting for whatever charge the battery happened to hold when the grid went down.
It helps to think of battery energy in three layers:
- Nominal capacity: everything the cells can physically store.
- Usable capacity: nominal capacity x maximum DoD. This is what the system lets you draw.
- Available at outage start: usable capacity x state of charge when the power fails, then reduced by inverter losses on the way to your outlets.
Every sizing decision should be built on the second and third layers, never the first.
Nominal vs usable: how to read the spec sheet
Home battery makers do not all report capacity the same way. Some list only usable energy. Some list both total and usable. Others lead with nominal capacity and put the DoD in small print. Before comparing two systems, confirm you are comparing the same kind of number.
Look for the phrases “usable energy,” “usable capacity,” “total energy,” “nominal capacity” and “depth of discharge.” If a sheet gives only nominal capacity and a DoD percentage, do the multiplication yourself. If it gives a usable figure, use that directly and do not apply the DoD a second time.
| Nominal capacity | Max DoD | Usable capacity (nominal x DoD) | Delivered as AC (usable x 0.90) |
|---|---|---|---|
| 10 kWh | 100% | 10 x 1.00 = 10.0 kWh | about 9.0 kWh |
| 10 kWh | 90% | 10 x 0.90 = 9.0 kWh | about 8.1 kWh |
| 10 kWh | 80% | 10 x 0.80 = 8.0 kWh | about 7.2 kWh |
| 15 kWh | 90% | 15 x 0.90 = 13.5 kWh | about 12.2 kWh |
| 20 kWh | 80% | 20 x 0.80 = 16.0 kWh | about 14.4 kWh |
The last column assumes roughly 90% efficiency converting the battery’s DC power to household AC, a conservative typical figure. Real efficiency varies with the inverter and the load, and it tends to drop at very light loads.
Notice the bottom row. A 20 kWh nominal battery limited to 80% DoD delivers about the same energy as a 16 kWh battery that allows 100%. If you shopped by the big number alone, you would think the first one holds 25% more. It does not.
Why batteries hold energy back
Lithium cells wear faster when they are routinely drained to empty or held at completely full. Manufacturers protect them by setting a buffer at the top, the bottom or both. The tighter the buffer, the longer the battery tends to last, and the less energy you can use per cycle.
Chemistry drives most of the difference. Lithium iron phosphate (LFP), now the most common chemistry in home batteries, tolerates deep cycling well, so many LFP systems are rated for 90% to 100% DoD. Older nickel-based lithium designs often used shallower limits. Lead-acid batteries were commonly kept to about 50% DoD for reasonable life, which is why a lead-acid bank needs roughly twice the nominal capacity to match a lithium bank’s usable energy. For a deeper look at how chemistry affects cycle life, see our guide to battery lifespan by chemistry.
One more point: a battery advertised at 100% DoD usually still has a hidden buffer at the cell level. The “100%” means you can use all of the rated usable capacity, not that the cells are being driven to absolute zero. That is a good thing, and it is the reason the rating can be trusted.
Backup reserve: the setting that decides your outage
If your battery is paired with solar or a time-of-use rate plan, it probably cycles every day. It charges from solar or cheap grid power, then discharges in the evening to cut your bill. The backup reserve is the floor it will not go below during that normal cycling. Whatever is held in reserve is guaranteed to be there when the grid fails.
That makes the reserve the most important number for outage planning. In the worst case, an outage begins right after the evening discharge, and you start with only the reserve. Here is what that looks like for a battery with 13.5 kWh of usable capacity:
| Reserve setting | Worst-case energy at outage start | Delivered as AC (x 0.90) | Trade-off |
|---|---|---|---|
| 100% (backup only) | 13.5 x 1.00 = 13.5 kWh | about 12.2 kWh | Maximum outage protection, no daily bill savings |
| 50% | 13.5 x 0.50 = 6.75 kWh | about 6.1 kWh | Balanced, half the battery works for savings |
| 30% | 13.5 x 0.30 = 4.05 kWh | about 3.6 kWh | Good savings, thin protection overnight |
| 20% | 13.5 x 0.20 = 2.7 kWh | about 2.4 kWh | Mostly a savings device |
| 10% | 13.5 x 0.10 = 1.35 kWh | about 1.2 kWh | Barely enough to ride through a short blip |
With solar, a sunny day during the outage can refill the battery, so a low reserve is less risky. Without solar, the energy you start with is all you get until the grid returns or you recharge from another source.
Three related features are worth checking in your system’s app:
- Storm or weather-alert mode: some systems automatically charge to full when a severe weather alert covers your area. If yours does, turn it on.
- Manual reserve change: you can usually raise the reserve to 100% a day or two before a forecast storm, then lower it afterward.
- Utility or aggregator programs: if you enroll in a virtual power plant program, find out whether events can draw the battery below your reserve. Some programs respect your floor, others set their own.
Some systems also keep a small hidden reserve during an outage so the inverter can restart and accept solar charging the next morning. That energy is not available to your loads, so treat the low end of the gauge as a warning, not a cushion.
How DoD and reserve change outage runtime: a worked example
Take a modest set of essential loads for a home with a gas furnace:
- Refrigerator: about 1.5 kWh per day
- Chest freezer: about 1.0 kWh per day
- Modem and router: 15 W x 24 h = 0.36 kWh
- LED lights: 50 W x 6 h = 0.3 kWh
- Phones and a laptop: about 0.3 kWh
- Furnace blower: 500 W x 6 h of run time = 3.0 kWh
Total: 1.5 + 1.0 + 0.36 + 0.3 + 0.3 + 3.0 = about 6.5 kWh per day. Runtime is simply the AC energy available divided by daily use.
- 13.5 kWh usable, 100% reserve: 12.2 / 6.5 = about 1.9 days.
- Same battery, 30% reserve, worst-case timing: 3.6 / 6.5 = about 0.55 days, or roughly 13 hours.
- 15 kWh nominal at 80% DoD: 15 x 0.80 = 12 kWh usable, x 0.90 = 10.8 kWh AC, / 6.5 = about 1.7 days.
- 13.5 kWh usable, 100% reserve, no furnace load (3.5 kWh per day): 12.2 / 3.5 = about 3.5 days.
The same hardware can deliver 13 hours or nearly 2 days depending on one setting in an app. Load choices matter just as much: dropping the furnace blower nearly doubles runtime. To build your own load list, use our home battery sizing chart and worksheet, then plug the usable figure from this article into it.
Other things that shrink usable energy
- Cold temperatures: lithium batteries deliver less energy in the cold, and many systems limit or block charging near freezing. A battery in an unheated garage in a northern state may give noticeably less than its rating during a winter outage.
- Standby consumption: the inverter, gateway and monitoring hardware draw power just to stay on. As an example, a system that idles at 30 W uses 30 x 24 = 720 Wh per day before any appliance runs.
- Aging: capacity fades with years and cycles. A common warranty term guarantees around 70% of original capacity at the end of the warranty period. On a 13.5 kWh battery, that is 13.5 x 0.70 = about 9.5 kWh. Check your own warranty wording.
- Conversion losses at light loads: powering a single small device through a large inverter can be much less efficient than the 90% typical figure.
How to compare two batteries fairly
- Find the usable capacity for each. If only nominal is listed, multiply by the stated DoD.
- Multiply usable capacity by about 0.90 to estimate AC energy delivered.
- Decide what reserve you will actually run, and multiply by that for your worst-case outage start.
- Subtract a realistic allowance for cold and standby use if they apply to your home.
- Check the warranty end-of-term capacity, since that is what you will have in year ten.
- Compare continuous power output separately. Energy (kWh) decides how long; power (kW) decides what can run at once.
Our roundup of the best whole-house battery backup systems lists usable capacity for each pick, which makes this comparison easier. Installation, critical loads panels and any change to which circuits the battery backs up are work for a licensed electrician. The reserve setting itself is a safe app change you can make yourself.
Suggested reserve settings by situation
| Your situation | Suggested reserve | Why |
|---|---|---|
| Battery with no solar, bought for backup | 100% | No daily recharge source, so every kWh should be waiting for the outage |
| Solar plus battery, outages rare and short | 20% to 30% | Daily savings matter more, and solar refills the battery |
| Solar plus battery, frequent or long outages | 40% to 60% | Covers a night of essentials even with bad timing |
| Medical equipment in the home | 50% or higher, 100% during storm season | The cost of running short is far higher than lost savings |
| Severe storm forecast within 48 hours | 100% | Start the outage full, then lower the reserve afterward |
These are starting points, not rules. Revisit them each season, especially before hurricane season or winter.
Bottom line: the capacity on the box is the least useful number on the spec sheet. Multiply nominal capacity by DoD to get usable kWh, multiply by about 0.90 for inverter losses, then multiply by your reserve setting to see your worst-case outage start. Size your system and choose your reserve from that final number, and you will know how long the lights stay on before the storm arrives.
Frequently Asked Questions
Is 100% depth of discharge bad for a home battery?
Not when the manufacturer rates it that way. A 100% DoD rating means you can use all of the rated usable capacity, and the system still keeps a protective buffer at the cell level. Routinely draining any battery to empty does add some wear, so a modest daily reserve can help longevity, but using the full battery during an outage is exactly what it is designed for.
What backup reserve should I set if I have solar?
Many homeowners with solar and infrequent outages use 20% to 30%, which keeps most of the battery working to lower bills. If outages are common in your area or someone depends on powered medical equipment, 40% to 60% or more is safer. Raise it to 100% when a major storm is forecast.
Do portable power stations have depth of discharge too?
Yes, but most power stations already report usable capacity in watt-hours, and the 0% on the display includes a built-in buffer. You still lose roughly 10% to 15% converting to AC power. Our power station runtime chart shows what common sizes actually run once those losses are counted.
Does depth of discharge affect my battery warranty?
It can. Many home battery warranties cover a set number of years, a total energy throughput in kWh, or a minimum remaining capacity, whichever comes first. Cycling deeper every day uses up throughput faster, so read the warranty terms before setting a very low daily reserve.